Configuring Power Restore States
Revision as of 12:37, 2 March 2019 by HLandau (talk | contribs) (HLandau moved page Talos II/Configure Power Restore States to Configuring Power Restore States: Not Talos specific anymore)
Contents
Purpose
This guide explains how to configure RCS OpenPOWER systems to power on immediately when power is applied to a system.
Applicability
All RCS OpenPOWER systems.
Changing power restore settings
The BMC controls the system power state. As such, the power restore state is configured on the BMC itself. After gaining SSH access to the BMC, you can configure the system power restore state as follows.
Keep chassis power off after power application
busctl set-property xyz.openbmc_project.Settings /xyz/openbmc_project/control/host0/power_restore_policy xyz.openbmc_project.Control.Power.RestorePolicy PowerRestorePolicy s xyz.openbmc_project.Control.Power.RestorePolicy.Policy.AlwaysOff
Always turn chassis power on after power application
busctl set-property xyz.openbmc_project.Settings /xyz/openbmc_project/control/host0/power_restore_policy xyz.openbmc_project.Control.Power.RestorePolicy PowerRestorePolicy s xyz.openbmc_project.Control.Power.RestorePolicy.Policy.AlwaysOn
Restore last chassis power state after power application
busctl set-property xyz.openbmc_project.Settings /xyz/openbmc_project/control/host0/power_restore_policy xyz.openbmc_project.Control.Power.RestorePolicy PowerRestorePolicy s xyz.openbmc_project.Control.Power.RestorePolicy.Policy.Restore