System Package 2.10 Release Notes
BMC
- No change
PNOR
- Update hostboot to latest upstream version
- Update skiboot to latest upstream version
- Update petitboot to latest upstream version
- Update hcode to latest upstream version
- Update skiroot to Linux 6.6.y stable branch
- Enable Infiniband drivers in skiroot
- Fix sporadic crash on paired-core machines (higher than 8 core) under specific workloads
- Compress hostboot runtime to free up additional space in the BOOTKERNFW partition
- Enable firmware component signature checks during IPL by default. Note that this uses the well-known (insecure) public transitional key in the official firmware builds, but makes the transition to a machine owner's key easier should the user wish to enable a secure boot chain using their own signing keys.
FPGA
- No change
Known Issues
- New BMC cannot IPL old PNOR and vice versa (CANTFIX)
- Lockdown of P2A bridge for security breaks AST2500 VGA passthrough -- ast driver in guest cannot read configuration due to lockdown, and qemu does not pass host device tree information with VGA configuration data to guest kernel.
- Certain DIMMs may not function in Slot 0. This is not a defect in the Blackbird planar, it is a memory VPD issue that is being worked by Raptor and the IBM memory team. Future firmware updates are expected to address this problem.
- Upgrading from a BMC that has been manually edited to add or remove users can result in loss of SSH access after the upgrade has completed. The root cause is that
/etc/passwd
is retained verbatim across updates if modified, and as a result the newsshd
user is not present in the upgraded firmware environment.- Prior to upgrading such a BMC, the following line should be added to
/etc/passwd
on the BMC:sshd:x:996:995::/var/run/sshd:/bin/false
- Alternatively, the files
/etc/passwd
and/etc/group
can be removed immediately before reboot to apply the update. Caution should be used with this method, as failure to apply the update could then result in a requirement to use a BMC serial cable or external SPI flasher to recover.
- Prior to upgrading such a BMC, the following line should be added to